RAY Egelhof - High heat resistant industrial Gas burners “HTG-NA” - series
RAY Egelhof - High heat resistant industrial gas burners “HTG-NA” - series are used at all kinds of firing kilns, furnaces and post combustion chambers and are suitable for firing of all technical combustible gases, biogases, hydrogen, LPG and process gases.
RAY Egelhof - “HTG-NA” – series burners are available in a capacity range from 116 kW (396 MBTU) - 5.400 kW (17,845 MBTU).
For more information, please get in contact with us - our team will be happy to support you!
Design of the burner
You will find the matching picture in the slider on the right!
1. Burner plate | 2. Burner housing |
3. Gas nozzle | 4. Gas pipe with air baffles |
5. Refractory lining | 6. Ceramic mat |
7. Insulating insert | 8. Gas connection flange |
9. Ignition electrodes | 10. Flame sensor bracket |
Operating range
Burner operating range in relation to combustion air temperature
Burner type | 20°C | 200°C | 500°C | 600°C | 700°C | 800°C | Weight burner with burner plate |
kW MBTU |
kW MBTU |
kW MBTU |
kW MBTU |
kW MBTU |
kW MBTU |
kg | |
HTG-NA 40 |
116 396 |
76 259 |
47 160 |
41 140 |
35 119 |
31 106 |
ca. 35 |
HTG-NA 50 |
174 594 |
110 375 |
70 239 |
58 198 |
52 177 |
48 164 |
ca. 42 |
HTG-NA 65 |
291 993 |
186 635 |
116 396 |
99 338 |
87 297 |
79 270 |
ca. 50 |
HTG-NA 80 |
465 1,587 |
302 1,030 |
186 635 |
163 556 |
140 478 |
126 430 |
ca. 65 |
HTG-NA 100 |
756 2,579 |
488 1,665 |
302 1,030 |
262 894 |
227 775 |
205 699 |
ca. 97 |
HTG-NA 125 |
1.160 3,958 |
756 2,579 |
465 1,587 |
407 1,389 |
350 1,194 |
314 1,071 |
ca. 115 |
HTG-NA 150 |
1.510 5,152 |
983 3,354 |
605 2,064 |
529 1,795 |
453 1,546 |
408 1,392 |
ca. 142 |
HTG-NA 200 |
2.910 9,929 |
1.860 6,346 |
1.160 3,958 |
1.020 3,480 |
872 2,975 |
785 2,678 |
ca. 190 |
HTG-NA 250 |
4.070 13,887 |
2.560 8,735 |
1.630 5,562 |
1.400 4,777 |
1.280 4,367 |
1.100 3,753 |
ca. 255 |
HTG-NA 300 |
5.230 17,845 |
3.370 11,498 |
2.090 7,131 |
1.740 5,937 |
1.630 5,562 |
1.410 4,811 |
ca. 310 |
HTG-NA 350 |
ca. 6.100 20,813 |
ca. 3.930 13,409 |
ca. 2.440 8,325 |
ca. 2.030 6,926 |
ca. 1.900 6,483 |
ca. 1.640 5,596 |
ca. 415 |
Note: Burner operating range refers to standard furnace and combustion air conditions.